    Wonder why your Aircon is not working ? Wonder no more! List of Error Codes

    Aircon Blinking Lights and their Malfunction Codes


    Disclaimer:


    These error codes are provided based on the best of our knowledge, the same set of error codes may differ  
    depending on the models. We are not liable for any mistakes in the malfunction codes:

    source is from : http://www.astiquer.com


    When your "timer" light blinks, it is not that your timer is faulty. Most manufacturer uses any of the LED lights blinking to 
    indicate a faulty air conditioning system.

    "Inverter" air conditioner is more powerful when in comes to error code, because the indoor unit and outdoor unit were 
    already linked up and communicating, a non-inverter condenser  simply accepts a 230vac voltage to start turning the 
    compressor and fan, so the indoor and outdoor is not really "communicating".

    DAIKIN error codes:

    AO Indoor Error of external protection device
    A1 Indoor PCB defect
    A3 Indoor Malfunction of drain Level control system
    A5 Indoor Freeze-up prevention
    A6 Indoor Fan motor lock, Overload
    A7 Indoor Malfunction of swing motor flap
    A9 Indoor Malfunction of EEV
    AF Indoor Drain level above limit (clogging)
    AJ Indoor Malfunction of capacity set device
    C3 Indoor Malfunction of drain thermistor
    C4 Indoor Malfunction of liquid pipe thermistor
    C5 Indoor Malfunction of gas pipe thermistor
    C7 Indoor Lower louvre limit switch/motor
    C9 Indoor Malfunction of air thermistor
    CC Indoor Malfunction of moisture sensor
    CA Indoor Malfunction of discharge air thermistor
    CJ Indoor Malfunction of remote control thermistor
    CE Indoor Malfunction of radiant heat sensor
    E0 Outdoor Activation of outdoor safety device
    E1 Outdoor PCB defect
    E3 Outdoor Activation of high pressure switch
    E4 Outdoor Activation of low pressure switch
    E5 Outdoor Activation of compressor over heat protection
    E5 Outdoor Compressor motor lock
    E6 Outdoor Compressor start up error
    E6 Outdoor Standard compressor lock/overcurrent
    E7 Outdoor Fan motor lock, Overload
    E8 Outdoor Inverter input overcurrent
    E9 Outdoor Malfunction of EEV
    EA Outdoor Four way valve defective.
    F3 Outdoor Abnormal discharge pipe temperature
    F6 Outdoor Refrigerant overcharged
    FC Outdoor Low pressure drop.
    H3 Outdoor High pressure switch defect
    H4 Outdoor Low pressure switch defect
    H6 Outdoor Compressor motor position detection sensor error
    H7 Outdoor Fan motor position detection sensor error
    H8 Outdoor Current transformer error
    H9 Outdoor Malfunction of air thermistor
    J1 Outdoor Malfunction of pressure sensor
    J2 Outdoor Current sensor malfunction
    J3 Outdoor Malfunction of discharge pipe thermistor
    J4 Outdoor Low pressure saturation thermistor
    J5 Outdoor Malfunction of suction pipe thermistor
    J6 Outdoor Malfunction of heat exchanger thermistor
    J7 Outdoor Malfunction of heat exchanger liquid thermistor
    J8 Outdoor Malfunction of liquid pipe thermistor
    J9 Outdoor Malfunction of gas pipe thermistor
    JA Outdoor Malfunction of discharge pipe pressure sensor
    JC Outdoor Malfunction of suction pipe pressure sensor
    JH Outdoor Malfunction of oil temperature sensor
    L0 Outdoor Malfunction of inverter
    L3 Outdoor Electronic component box overheat
    L4 Outdoor Inverter cooling defect
    L5 Outdoor Comp motor ground fault, Short circuit
    L6 Outdoor Compressor motor grounding/short circuit
    L7 Outdoor Total input overcurrent
    L8 Outdoor Comp overload, Motor disconnected
    L9 Outdoor Compressor lock
    LA Outdoor Power unit malfunction
    LC Outdoor Transmission between inverter & outdoor
    P1 Outdoor Inverter over ripple
    P3 Outdoor Thermistor abnormality
    P4 Outdoor Power unit humidity sensor malfunction
    PJ Outdoor Failure of capacity set resistor
    U0 System Shortage of refrigerant or EEV failure
    U1 System Negative phase, Open phase
    U2 System Power supply insufficient
    U3 System Wiring check operation not executed
    U3 System Mismatch of indoor and outdoor units (Split only)
    U4 System Transmission between indoor units
    U5 System Transmission to remote controller
    U6 System Malfunction transmission outdoor to BP unit
    U7 System Transmission between outdoor units
    U7 Outdoor Malfunction between outdoor boards(RMX/RX RK)
    U8 System Transmission between master & slave R/C
    U9 System Transmission error between indoor to outdoor
    UA System Excessive number of fancoils
    UC System Address duplication of central controllers
    UE System Transmission error between indoor & central
    UF System Refrigeration system not set/wiring - piping
    UF System Terminals 1 and 3 crossed (Split/Skyair)

    If your DAIKIN remote controller comes with a "test" button, use it. Otherwise press the Temperature UP, Temperature 
    DOWN and the MODE buttons all at the same time.

    You will see 00 on the remote controller. The first "0" will be blinking.

    Stand facing the particular air conditioner you wanted to test.

    Now press the Temperature UP button, "0" will become "A" and the air conditioner will respond with either a single beep or 
    double beep.

    Carry on pressing the Temperature UP button and listen to the beeping sound, stop when you hear a double beep.
    For example: it is now showing "C0".

    Now press the MODE button, the second "0" will be blinking.
    Now press the Temperature UP button, "0" will become "1" and the air conditioner will respond with either a  double beep 
    or a continuous beep.

    The continuous beep is the error code. For example "C4", it means it is a faulty liquid pipe thermistor.

    Note: Please use this wonderful feature provided by DAIKIN to have a rough idea of what is the problem with your system, 
    it is especially useful if yours is an inverter.


    Mitsubishi (Mr Slim) error codes:

    The Mr. Slim error code is represented by the number of blinks on the LED (light emitting diode), rather, those lights you 
    see on the air conditioner:



    Samsung error codes:

    The Samsung wall mounted air conditioner error code is represented by blinks on the different LEDs (light emitting 
    diode), rather, those lights you see on the air conditioner, quite logical indeed:



    LG (lmn 2065c3l)

    The lmn2065c3l error code is represented by the number of blinks on the LED (light emitting diode), rather, those lights 
    you see on the air conditioner:



    Hitachi (Ras-model) error codes:

    The ras model error code is represented by the number of blinks on the LED (light emitting diode), rather, those lights 
    you see on the air conditioner:


    Sanyo (inverter, sap kmv series) error codes:

    The above model error code is represented by the combination of blinks and lighted LED on the 3 different LED (light 
    emitting diode), operation, swing and timer.
    *    blinking
    0   lighted up



    Fujitsu (hard wired series)

    When EE:EE is displayed, press "energy save" and  "zone control" simultaneously for about 5 secs. The lcd display will 
    display the relevant error code.

    Monday
    Dec272010

    15 Tips to reduce electrical bill

    1. Start by finding a professional aircon maintenance team to inspect and clean your air-conditioner. A well-maintained unit uses less electricity.

    2. Have your fancoil unit installed on a wall that is cooler and doesn't have any electrical appliances that can cause heat like a lamp or television as it will interfer with the thermostat making the aircon work even harder.

    3. Keep your condenser (outdoor) unit clean by removing grass, leaves and other debris that are stuck on the coil. Also do not place any things such as laundry near to the condenser. Every month, uses a vacuum cleaner connection with a brush, lightly sweep in the direction of the condenser's coil or uses a low pressure water and spray on the coil during raining times.

    4. Set your air-conditioner not cooler than 25*C.

    5. When buying a room air-conditioner, make sure it is properly sized. A larger than needed air-conditioner cycles on and off more frequently, reducing its efficiency. Frequent cycling make indoor temperatures fluctuate more and creates a less comfortable environment.

    6.Check the refrigerant charge. The circulating fluid in your air conditioner is a special refrigerant gas that is put in when the system is installed. If the system is overcharged or undercharged with refrigerant, it will not work properly. You may need to call a professional aircon maintenance team to check the fluid and adjust it appropriately.

    7.try to not use a dehumidifier at the same time your air conditioner is operating. The dehumidifier will increase the cooling load and force the air conditioner to work harder, which in turn increases your utility bill.

    8.The unit should be level when installed, so that the inside drainage system and other mechanisms operate efficiently. If possible, install the unit in a shaded spot on your homes north or east side. Direct sunshine on the units outdoor heat exchanger decreases efficiency by as much as 10%. You can plant trees and shrubs to shade the air conditioner, but do not block the airflow.

    9.Dont place lamps or televisions near your air-conditioners thermostat. The thermostat senses heat from these appliances, which can cause the air conditioner to run longer than necessary.

    10.Install ceiling fans. Fans can make you feel 3 to 8 degrees cooler, allowing you to adjust your AC to a higher temperature and still feel just as cool. (NY Times)  Put the wind-chill factor to work for you.

    11.Take a shower. A quick, cool shower can keep you cool for quite a while afterward.  And the water cost is trivial compared to the electric cost.

    12.Set a timer to turn off about the time you fall asleep.

    13.Clean ur filters or replace your AC filter every month. A dirty filter makes your AC work harder, which uses more electricity.

    14.Change ur old aircontoday's, AC's use 30-50% less electricity than 15-year-old models. Whatever system you get, look at the energy ratings The higher, the better.

    15.Get a good inverter system with 4 ticks energry savings

     

    

    Monday
    Dec272010

    Inverter VS non-Inverter

    Brief description of Non-Inverter Systems
    The compressor and its motor are manufactured to operate at constant speed or single speed only. In simple terms, it is either in the on (Full Power) or off (No Power) mode.

    as long as it is a Non Inverter, you will get the 'cut in' and 'cut out' of the compressor. In other words, everytime the room reaches the pre-set temperature, the compressor will stop working. And when it senses an increase in temperature, it will start running again. Thus through out the night, you will experience the 'start and stop' of the compressor.

    Due to the frequently start-stop of the compressor, more eletricity will be comsumed as more power is needed to start the system all over again whenever it stopped. In addition, the compressor will also have a shorter life span.

    Brief description of Inverter Systems
    an inverter air conditoner attains the set temperature, instead of 'switching off' like a non inverter, it uses the minimum power to ensure your room is maintain at the required temperature and adjust smoothly with response to any changes in the cooling load. Overall, you use less electricity.

    Inverter Systems are generally of higher quality especially those using R410A refrigerant.

    Differences
    the price difference between both can easily cost up to $600~1000
    Inverter condenser units are very quieter and has a longer life span
    Inverter Systems maintenance will cost more than a non-inverter systems
    Replacement Parts will be more expensive for Inverter Systems